Article page

EFFECT OF DIFFERENT TYPES OF DRY SWABS AND THEIR STORAGE CONDITIONS ON THE INOCULATION OF CORYNEBACTERIUM DIPHTHERIAE


DOI: https://doi.org/10.51620/0869-2084-2022-67-5-296-300

Full Text:


Abstract

The results of evaluating the effectiveness of C. diphtheriae inoculation using different types of dry swabs in studies simulating various conditions of its storage at the preanalytical stage of a laboratory study for diphtheria are presented. A typical toxigenic strain of C. diphtheriae biovar gravis No. 665 was used. A commercial dry, sterile cotton swab probe (Ningbo Greetmed Medical Instruments Co., LTD, China), a commercial dry, sterile swab probe (plastic and viscose) (COPAN, Italy), tufters with a fluffy probe-tampon on a polystyrene applicator, standard (DELTALAB, SL, Spain). The tampons were pooled with a 24-hour bacterial culture of C. diphtheriae, then immediately seeded on Tellurite-containing blood agar and Corynebacagar. Storage conditions were simulated for 3 hours: at room conditions +(20-25)°C, in the refrigerator +(4-8)°C, in a thermostat +(37±1)°C. Optimal storage of C. diphtheriae on all three types of dry swabs at + (4-8) ° C; at +(20-25)° C - growth is observed when seeding from a cotton swab; in a swab with a fleecy probe-tampon, a decrease in the inoculation of C. diphtheriae was noted; when using a viscose swab - a significant loss of C. diphtheriae. At +(37±1)°C, a significant decrease in the inoculation of C. diphtheriae on all three types of tampons was noted, up to the absence of growth when using a viscose tampon. To exclude the loss of C. diphtheriae, it is necessary to observe the conditions for taking and storing biological material at the preanalytical stage of a laboratory study, which will improve the quality of laboratory microbiological studies for diphtheria infection.


Для цитирования: Пименова А.С., Гадуа Н.Т., Борисова О.Ю., Миронов А.Ю., Афанасьев М.С., Афанасьев С.С. Влияние разных типов сухих тампонов и условий их хранения на высеваемость Corynebacterium diphtheriae. Клиническая лабораторная диагностика. 2022; 67(5): 296-300. https://doi.org/10.51620/0869-2084-2022-67-5-296-300

For citation: Pimenova A.S., Gadua N.T., Borisova O.Yu., Mironov A.Yu., Afanasiev M.S., Afanasiev S.S. Effect of different types of dry swabs and their storage conditions on the inoculation of Corynebacterium diphtheriae. Klinicheskaya Laboratornaya Diagnostika (Russian Clinical Laboratory Diagnostics). 2022; 67(5): 296-300 (in Russ.). https://doi.org/10.51620/0869-2084-2022-67-5-296-300

Refbacks

  • Refbacks are not listed


Creative Commons License
Контент доступен под лицензией Creative Commons Attribution 3.0 License.

ISSN: (Print)
ISSN: (Online)